SKU: AT-UHD-CLSO-601
Scenario: Setting a UHD-CLSO-601 to a static IP address via RS232/serial
Steps:
To perform this process, you will need:
- 1 x PC with a serial emulator (see below for Hterm link)
- 1 x USB to Serial cable
- 1 x DB9 to bare wire cable
Setting up a static IP
- Using a RS232 cable and terminal emulator such as HTerm connect to the matrix
- Port settings are: 115200 baud rate, 8 bit, 1 stop bit, no parity, no flow-control
- Confirm your serial program will send commands with a carriage return (enable this setting)
- Send the “IPDHCP off” command (followed by the carriage return):
- With DHCP turned off, you are now able to set a static IP address of your choosing
- Send following command “IPStatic xxx.xxx.xxx.xxx yyy.yyy.yyy.yyy zzz.zzz.zzz.zzz” for X use your desired IP address, for Y use your networks subnet mask, for Z use your network's default gateway
- Example:
- After following these steps, you should now be able to access the switch using the new static IP address.
Article ID: KB01379